FAU_GEN.1 Audit data generation
Hierarchical to: No other components.
FAU_GEN.1.1 The TSF shall be able to generate an audit record of the following auditable events:
a) Start-up and shutdown of the audit functions;
b) All auditable events for the [selection: minimum, basic, detailed, not specified] level of audit; and
c) [assignment: other specifically defined auditable events].
FAU_GEN.1.2 The TSF shall record within each audit record at least the following information:
a) Date and time of the event, type of event, subject identity, and the outcome (success or failure) of the event; and
b) For each audit event type, based on the auditable event definitions of the functional components included in the PP/ST, [assignment: other audit relevant information]
Dependencies: FPT_STM.1 Reliable time stamps